SA404 220V AC 4 Wire

SA404 wire connection is the basic connection for 220V AC Motorized with ON/OFF Function.

Details of the SA404 connections are as follows

sa404 220V AC on off
  • Connect the 220V Phase to the Red colour wire.
  • Connect the 220V AC Neutral to the Black colour wire. 
  • Connect the Green wire to the 220V AC Phase whenever the valve needs to be opened. 
  • This supply to the green wire can be given thru PLC, Relay Float switch.
  • As long as you need to open the valve, the green terminal should be connected to phase of 220V AC.
  • Note: Since the valve is stay put on power failure type. Red and black to be connected to phase and neutral of 220V AC always.
  • Power consumption during valve close is zero and open is around 20mA. Actual power consumption takes during the movement of valve. 